Clear Vision DRE series

Economic Digital Radiography System

DRE 140 / DRE 150

  • Operation Software 
    ExamVue software presents a comprehensive set of X-ray image analysis tools through the use of an fast and easy-to-use interface. ExamVue offers high performance image processing and measurement functions.
  • X-ray Generator 
    High frequency generator ensures minimum patient dose, excellent reproducibility, and superior image contrast.
  • Flat panel detector 
    Flat panel detector for digital radiographic applications delivers high sensitivity, high resolution, low noise and superb image quality. Portable flat panel detector provides unlimited clinical applications.
  • Tube stand 
    Ergonomically designed tube stand provides the operator with faster and easier movement for table and stand examinations.
  • Bucky stand 
    Wide range of vertical travel (400 ~ 1,800mm) allows exposures to be carried out from the cervical spine to the lower extremities.
  • Bucky table 
    The robust table design allows the examination of obese patients, with a table weight capacity of up to 150kg. Due to the footswitch integrated into the table base the operator can care the patient safely without any unexpected movement of the tabletop.

The system can be used as a dual 17” X 17” detector system or a single 14” X 17” detector system.

SPECIFICATIONS OF THE SYSTEM

Generator DRE140 DRE150
Max. Output 40kW DRE150
mA range 10 ~ 500mA 10 ~ 630mA
kV range 40 ~ 125kV 40 ~ 150kV
mAs range 0.4 ~ 630mAs 0.1 ~ 630mAs
Power 
supply
1Ø 220VAC 
50/60Hz
3Ø 380VAC 
50/60Hz
Exposure 
time
0.004 ~ 10sec 0.001 ~ 6.3sec
No. of APR 216 1,024
Option AEC AEC /
High speed rotor /
DAP
X-ray tube DRE140 DRE150
Focal spot 1.0/2.0mm 0.6/1.2mm
Anode heat
capacity
100kJ (140kHU) 210kJ (300kHU)
Target angle 16° 12°
Voltage
range
40 – 125kV 40 – 150kV
Weight 16kg 18kg
Permanent
filtration
0.9mmAl 0.9mmAl
Flat panel detector DRE140/150 DRE140/150
Scintillator CsI CsI
Pixel pitch 143um 143um
Resolution 3.7lp/mm 3.7lp/mm
MTF 36%
(2.0lp/mm,
70kVp, 1×1)
36%
(2.0lp/mm,
70kVp, 1×1)
DQE 70% 70%
Active Area 43 x 43.9cm 35 x 43cm
Pixel matrix 3,008 x 3,072 2,448 x 2,984
AD
conversion
14 bits 16 bits
Energy
range
40 ~ 150kVp 40 ~ 150kVp
Power
supply
1Ø 100 ~ 
240VAC 50/60Hz
1Ø 100 ~ 
240VAC 50/60Hz
Dimension 512 x 495 x 43mm 460 x 384 x 15mm
Weight 16kg 3kg
Collimator DRE140/150
Power
supply
1Ø 24VAC 50/60Hz
Max.
kVp shield
35 x 35cm at SID 65cm
Inherentr
filtration
1.2mmAl
Lampr
luminosity
Over 160Lux
Lamp time 30sec
Field sizer
control
Manual

TUBE STAND

Vertical travel distance 1,400mm
Transverse travel distance 260mm
Min. Tube height (from floor) 550mm
Max. Tube height (from floor) 1,950mm
Column rotation ±90°
Tube rotation ±180°
Longitudinal travel distance 2,400 ~ 3,000mm
(floor ceiling fixed type)
1,500mm (floor fixed type)
Power supply 24VDC, 3A
Weight DRE140/150

BUCKY STAND

Vertical travel distance 1,400mm
Min. Tube height (from floor) 400mm
Max. Tube height (from floor) 1,800mm
Power supply 1Ø 16 ~ 24VAC 50/60Hz
Weight 120kg
Application DRE140/150

BUCKY STAND

Table top size 2,000 x 745mm
Table top height 670mm
Table top material Acryl
Longitudinal Travel distance ±280mm
Transverse travel distance ±140mm
Bucky travel distance ±230mm
Max. patient weight Max. 150kg
Power supply 1Ø 220VAC 50/60Hz
Weight 160kg
Application DRE140/150

TYPES OF SYSTEM

Clear Vision DRE 140/150

Single Detector (14” X 17” or 17” X 17”)

Bucky Stand + Tube Stand system

  • Configuration
    Bucky stand, Tube stand(floor mounted or floor ceiling), Generator, PC&Monitor, Acquire software, Flat Panel Detector, Collimator

Clear Vision DRE 140/150

Single Detector (14” X 17” or 17” X 17”)

Tube Stand + Bucky Table (4way) system

  • Configuration
    4Way Bucky table, Tube stand(floor mounted or floor ceiling), Generator, PC&Monitor, Acquire software, Flat Panel Detector, Collimator

Clear Vision DRE 140/150

Single Detector (14” X 17” or 17” X 17”)

Dual Detector (14” X 17” or 17” X 17”)

Bucky Stand + Tube Stand + Bucky Table (4way) system

  • Configuration
    4Way Bucky table, Bucky stand, Tube stand(floor mounted or floor ceiling), Generator, PC&Monitor, Acquire software, Flat Panel Detector, Collimator

CONFIGURATION OF THE SYSTEM

Components DRE140 with
fixed dual FPD
DRE140 with
portable FPD
(with CR/film)
DRE150 with
fixed dual
FPD
DRE150 with
portable FPDl
(with CR/film)
40kW
Generator
  
50kW
Generator
  
17" x 17"
Flat panel
detector
14" x 17"
Flat panel
detector
150kV
X-ray tube
  
125kV
X-ray tube
  
Basic
Configuration
Tube stand, Bucky stand, Bucky table, PC & monitor, Acquisition Software
– upgradable to floor mounted Tube stand
– for international sales

EXAMVUE SOFTWARE

Optimized UI design for Touch screen
Multi-task Patient
Imaging and Annotation Tools
(Window level, Zoom, Pan, Crop, Invert, Rotation, Angle, Label, Text)
Powerful User Features
(Image stitching, Image import / export, Image comparison, Multi view, Image expansion, Full screen, Auto collimation, Reject/Accept)
Smart Window Level
DICOM3.0 Compatibility
Post Image processing mode for each body part
Changeable Skin color
(Green Tea, Strawberry, Mint, Chocolate, Banana, Vanilla)

X-Ray JPI